Issue Reported:

None of the client are able to register with SCCM 1610 and getting error as below screen shots.

LocationService.log /ClientIDManagerStartup.log

Solutions:

Step 1:  Verify random client properties and found Client certificate shows as None.

Step 2: Verified AD level DNS record as showing error on LocationService.log,  Found finding records is not available in active directory as client contacting other DNS which no longer active.

Step 3: Go to the client system>Click on run>Type control smscfgrc and enter

You will see Configuration Manager Properties>Click on Site Tab and enter site code which is showing in AD as here example H01 click apply and okay.

Step 4: Wait for while and look the LocationService.log /ClientIDManagerStartup.log you will see client get register as well as client get certificate based on configurations.  Here its showing as Self-Signed.

After doing above steps client start reporting to as normal and issue fixed.

Note: You can use ClientActionsTool for multiple system changing site codes.

Happy Learning!!!

Thanks&regards,
Haresh Hirani
Email: [email protected], [email protected]
Facebook https://www.facebook.com/Hiraniconfigmgr-120189361980772/
Follow us: https://www.linkedin.com/in/hiraniconfigmgr 
Twitter: https://twitter.com/hiraniconfigmgr

Author

  • Hi, I Haresh Hirani, I am the person behind this webpage. Welcome to my page, Thank you for visiting the website and my page! My website is all about Microsoft technologies. More about ConfigMgr and all other technologies which are interesting for me. However, larger percentage of my posts are related to SCCM. Normally, like to post the interesting issues which I came across in my day to day tech life. you will find only solutions which comes on my day to day life.

- Advertisement -spot_img

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Latest posts